Our revenue grade meter for utility customer, distribution, generation, transmission meters available with both 0.1 % class energy accuracy with certification to the ANSI C12.20 & 0.2 % class energy accuracy. The meter offers advanced revenue metering capability, including extensive load profiling, transformer line loss, and CT/PT compensation. Its SCADA capability consists of multiple serial and Ethernet communication ports, FOB and multiple protocols, including Modbus, DNP3, and IEC 61850. Meters can be connected to wireless two way communication with cyber security, primary surge suppression , Built-in I/O / External I/O and Compatible with EnergyPQA.com™ cloud-based energy management system.
Loaded with excellent metering capabilities, our meters has continued with customers once they start using, this is one of the Highly Accurate metes for Grid Metering and Power Generation
Electro Industries’ 0.5% Class electrical panel meters comes with communication capabilities. Utilizing bright and large 0.56″ LED displays, this unit is designed to be installed in electrical panels and switchgear for visibility from distance. a unique anti-dither algorithm to improve reading stability. The unit utilizes high speed DSP technology with high resolution A/D conversion to provide stable and reliable measurements.
Availability: Both in Transducer Model (Without display) & Meter model
Measurement Capabilities : Volts, Amps, kW, kVAR, PF, kVA, Freq, kWh, kVAh, kVARh & % of Load Bar for Analog Meter Perception
Communication Port with KYZ Pulse: RS485 (Option 485P) – This port allows RS485 communication using Modbus Protocol. Baud rates are from 9,600 to 57,600.
Display: 0.56″ LED displays
Sensing Method: RMS with Sampling at 400+ Samples per Cycle on All Channels Measured Readings Simultaneously
Size: H4.85 x W4.85 x L4.25 in.
To protect critical billing information, the meter records and logs the following with a time stamp:
Simultaneous Voltage and Current Waveform Recorder
EIG meters provide the pre-fault and post-fault event recording / Waveform records are programmable to the desired sampling rate.
The meter’s advanced DSP design allows Power Quality triggers to be based on a 1 cycle updated RMS. The meter stores waveform data in a first-in/first-out circular buffer to insure data is always recording. The unit records up to 512 or 1024 or up to 50 MHz samples per cycle for a voltage sag or swell or a current fault event depending up on various models.
Waveforms at a sampling rate of up to 1024 samples/cycle on multiple power quality events, including surges, sags, and transients. 16-bit A/D conversion provides precise waveform resolution. Both voltage and current recording offer pre- and post-event analysis. Fault recording offers eight times full-scale capture capability. Waveform recording for wideband frequencies is also supported. You can program both hardware and software triggers to record a waveform. View waveforms through Communicator PQA ® software, the meter’s web browser, or the EnergyPQA.com® cloud-based energy management system. You can also download the waveforms to third party software for analysis. Analyze the waveforms to determine the source of power quality anomalies and then take steps to remedy the situation.
Power quality Measurement becomes basic necessity with many sectors are coming with various power electronics, solar power, and wind power , furnaces, SMS etc. Monitoring Power quality continuously is the only way to identify as well as understanding source of problems for rectification.
some inputs which can be further investigated with international standards.
OPTION : II
Measure power quality as per International standards IEC 61000-4-30 Class A Edition 3. Various measurements can be done as per standards: This is required as per CEA guideline in India.
Maximum Sampling Speed available: 1024 samples / cycle per voltage and current independently & 50 MHz based on specific requirement.
Implementation of various methodologies to improvise the system for power quality improvement. This is possible only when there are sufficient information regarding source and type of power quality problems.
Contact for Power quality survey & improvement.
HIGH-END POWER QUALITY METER WITH BUILT-IN SYNCHROPHASORS : Phasor Measurement Unit (PMU) Improve Power System Stability
A phasor measurement unit (PMU) is a device used to estimate the magnitude and phase angle of an electrical phasor quantity (such as voltage or current) in the electricity grid using a common time source for synchronization.
Energy Management Software is a Next Generation Cloud-based Energy Management Solution, which works to offer a full energy management solution across an Enterprise, providing you with detailed usage comparisons and deep insights into power quality. It also utilizes machine learning to generate usage predictions, which help you to manage resources. The ability to view waveforms captured on voltage/current surges and sags and the limit/alarm feature let you be proactive in addressing issues with power quality before they result in damaged equipment or lost revenue.
The EnergyPQA.com® system is supported by the Communicator PQA® application and its Meter Manager PQA® automation component, which let you discover and group meters, configure meter settings, set up trending logs and automatic log retrieval, view real time readings, set system security, register meters with the Energy PQA.com® system, and perform related meter activities. When you sign up for the EnergyPQA.com® system, you get access to all of EIG’s metering and billing applications.
Energy Management System helps in several ways: